1999, NT - Intera 1.5T Mobile, Philips, MRI


ID Number: 45664
Updated: 03-05-17 
Date Posted: 03-05-17 
Quantity: 1 
Manufacturer: Philips 
Description: MRI 
Type: Mobile 1.5T 
Model: NT - Intera 1.5T Mobile 
DOM: 1999 
Condition: Good 
Older listings 'may' have already been sold.  
..
Location:  
Installed: ?  
Warranty:  
Availability:  
Inspect Date:  

Seller Type:

Dealer:

Dealer 

Sell Price:

Details: 1999 Philips NT-Intera 1.5T Mobile MRI System
1.5T Magnet Mobile• Ultra compact patient friendly design-only 1.57m (5.15 ft) in length.• 53cm FOV• Lightweight design – weighs just 2900 kg (6393 lbs) • Typical helium consumption between 0.03 l/h and 0.1/h, depending upon transportation condition• Mountain vent kit for traveling in mountainous terrain• Full travel-at-field capabilities to reduce setup times and cryogen consumption Patient Friendly Environment• Wide patient opening has a 110cm (43 inch) flare• Patient bore diameter is 60 cm (23.6 inch(, length 60 cm• Patient Weight Up to 250 kg (550 lbs)• Patient table can be lowered to a height of 52 cm (20.4 inch) • Horizontal travel of 200 cm (6.56 ft) within1.0 mm (0.04 inch) accuracy• Table speeds of 20mm/s to 180 mm/s• Adjustable fresh air supply and variable lighting• In-bore microphone• Hand-held nurse call button Physiological Synchronization • Peripheral Pulse• Respiratory• ECG• Physiological signals can be observed on the operator’s console monitorAdvanced ScantoolsExamCardsSENSEAdvanced Methods • Balanced FFE • DRIVE• CENTRA• ProSet• Black Blood ScanTools Applications Package • NeuroPlus• BodyPlus• OrthoPlus • CardiacPlus • AngioPlus Package • OncoPlus • PediatricPlus Package
Scan Planning and Setup • ExamCards • FlexPlan• TimeSave• AutoSurvey• RepeatScanAcquisition Modes • 2D and 3D acquisition modes• Image matrix sizes are freely selectable up to 1024 * 1024• Dynamic studies are possible with all imaging methods• Manual start • Spin Echo (SE): Single echo and asymmetric multiple echoes • Fast Field Echo (FFE)• Turbo Field Echo (TFE) • Turbo Spin Echo (TSE)• Echo Planar Imaging (EPI)• Inversion Recovery (IR) • Time of Flight (ToF) • Contrast Enhanced (CE)• Phase Contrast (PC)• Quantitative flow• CLEAR (Constant Level AppeaRance)• Cardiac gated breath-hold TFE • Single-slice multi-phase with Balanced FFE • 3D k-space shutter • Magnetization Transfer Contrast (MTC) • Fat Saturation: SPIR, ProSet, SPAIR• Perfussion• Bolus Trak• Mobi Trak• THRIVEProcessing and Post-Processing • Window width/level, zoom, pan, rotate, mirror• PicturePlus• Image annotation with text, arrows and lines • Distance and angle measurements, profile or histogram display and X-Y coordinate calculation • Regions of Interest (ROI) • Time Intensity Diagrams • Movie • Real-time display of MUP and MPR imagesConnectivity- ScanTools DICOM functionality includes: • Patient Study Query / Retrieve (SCU)
• Study Root Query / Retrieve (SCU)• MR Image /storage (SCU & SCP) Import/Export • Secondary Capture Storage (SCU & SCP) Import/Export • Grayscale Softcopy Presentation State Storage (SCU/SCP) Import/Export • Basic Grayscale Print Management (SCU) • Media Storage Service Write (on DVD/CD) & Read from DVD/CD and /or MOD (HW option)• Verification (SCU & SCP) Modality Worklist, MPPS and Storage CommitmentIHE SCHEDULED WORKFLOW MOBILE UNIT• 1998 Calumet Medical Coach• 1500lb patient lift - Fire Alarm• HVAC• Roll Door• Fire Alarm System• Generator (environmental support only)MEDRAD Sprectris MRI Dual Head Contrast Injector
 